Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call Point
The GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation.
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
GFE-MCPE
Conventional Manual Call Point
The GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation.
TECHNICAL SPECIFICATIONS | |
SUPPLY VOLTAGE | 20-30 V DC |
CURRENT - QUIESCENT | 200 uA |
CURRENT - DEVICE IN ALARM | 50 mA @ 24 V DC - Alarm Resistance 470 Ohms Max. |
CABLE SIZE | 0.5-2.5 mm² |
COLOUR / CASE MATERIAL | Red / ABS & Clear/ PC - Flame Retardant 94 V0 |
PROTECTION | IP24D |
OPER. TEMPERATURE | -10ºC to 55ºC |
MAX. HUMIDITY | 95% RH Non-Condensing |
DIMENSIONS | 92.6 (W) x 92.6 (H) x 60.1 (D) mm |
WEIGHT | 152 g |
ORDER CODE | |
GFE-MCPE-C | CONVENTIONAL MANUAL CALL POINT |
Description
GFE-MCPE
Conventional Manual Call Point
The GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Conventional MCP GFE-MCPE” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display -
0 out of 5
Honeywell Gent Conventional Heat Detector : Eco 1005
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty -
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Global Fire Addressable Panel JUNO NET
- Fully expandable system from 1-96 Loops with distributed intelligence for added security
- Up to 256 devices per loop (TBA)
- Up to 96 Loop sounders with 32 individually programmable addresses per Loop
- Compatible with major analogue addressable communications protocols
- 2 Fire output changeover relays and 1 Fault output relay (NC)
- Open collector outputs for Fire, Fault and pre-alarm remote indication
- 2 fully monitored sounder outputs on main panel and each sub panel
- Repeaters with optional integrated Sub-Panels (J-NET-REP + Loop Card)
- Redundant network communication via RS485, TCP/IP & Fiber Optics
- 384 programmable zones
- 512 fully programmable sounder and I/O groups
- Event Log 2000 entries FIFO
- Backlit LCD display 4 row * 40 characters
- Multiple programming options, onboard keypad, Remote IR(optional), PS2 Keyboard and GFE Connector software
- Windows™ based PC Graphics package ODYSSEY for alarm management and reporting(Optional)
- Multiple Language support (menu selectable)
- MODBUS (ASCII & RTU) and BMS support
-
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort
Reviews