Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
Power supply specification
Main supply voltage: 15Vdc to 26Vdc
Standby consumption 600 μA
Cable Connection: Max 2,5mm²
Alarm consumption : 0.6mA to 11mA (depending on tones)
Mechanical characteristics
Unit weight: 200g
Unit dimensions (in mm): Diam. 109mm Height 84mm
Unit row material: ABS
Unit colour: Red & White
Protection class: IP21C
Climatic characteristics
Operating temperature: 0°C to 50°C
Storage temperature: +10°C to +50°C
Operating relative humidity: 90%
Storage relative humidity: 85%
Description
AVSA.05 is an addressable sounder device build to be connected to a fire detection system (FDS). It is allocated and identified by an address; AVSA.05 is designed to be directly operational from a loop or line of a panel managing the 05 range protocol, it can be monitored and activated individually. Its round shape allows to be used on walls and ceilings. Every device has an integrated loop isolator. The choice of colours (white and red) allows a good sobriety of installation on any surfaces. AVSA.05 works with a piezoelectric cell that warrants a low loop or line consumption current. Its side hearings ensure an excellent sound broadcasting. The addressable sounder AVSA is certified with the standards EN 54-3 and EN 54-17.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable Indoor sounder AVSA05R” Cancel reply
Related Products
-
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box