Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
TECHNICAL SPECIFICATIONS | |
SUPPLY SPECIFICATION | DETAILS |
PRIMARY SUPPLY VOLTAGE - IN | 230 +10% -15% V AC |
PRIMARY SUPPLY VOLTAGE - OUT | 28.5 V DC nominal |
PRIMARY SUPPLY CURRENT - OUT | 1.7 A @ 28.5 V DC nominal (max.) |
SECONDARY SUPPLY VOLTAGE | 21.0 min. - 27.2 max. V DC - BAT charger o/p 28 V DC |
SECONDARY SUPPLY CURRENT OUTPUT | 1.1 Amp Maximum @ 200C |
INTERNAL BATTERY CAPACITY - MAXIMUM | 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries |
MAINS FUSE | 4 A -250 V Slow Blow - 20 mm |
BATTERY FUSE | 1.6 Amp - Resettable |
DETECTION CIRCUIT SPECIFICATION | |
NUMBER OF CIRCUITS | 2,4 or 8 |
ZONE CURRENT - QUIESCENT / ALARM | 4 mA / 60 mA - Maximum |
MAX. CABLE RESISTANCE / CAPACITANCE | 40 Ohms / 0.470 uF |
END OF LINE MONITORING | Active EOL - 10uF/50V Bipolar Electrolytic Aluminium Capacitor |
BS-5839 DETECTOR REMOVAL COMPLIANT | YES provided diodes are fitted to detector base |
DEVICES PER ZONE | 32 Maximum - EN54 pt.2 |
ALARM RESISTANCE VALUE | 270 - 1000 Ohms |
SOUNDER CIRCUIT SPECIFICATION | |
CURRENT OUTPUT | 2 outputs w/ 500mA max. current drive per circuit - fully monitored |
ALARM VOLTAGE / END OF LINE RESISTOR | 27.5 V DC Nominal / 10 K Ohms - 1/4 Watt |
AUXILIARY OUTPUTS SPECIFICATION | |
AUXILIARY RELAY OUTPUT | 1 Fire (COM |
RELAY CONTACT RATING | 50 V DC |
REMOTE INPUT SPECIFICATION | |
EVACUATION (CC) - DAY/ NIGHT MODE | Non-Latching |
RESET | Non-Latching |
MECHANICAL & OPERATING SPEC. | |
HUMIDITY | Max 95% RH Non-Condensing |
PROTECTION | IP30 |
OPERATING TEMPERATURE | -10ºC to 50ºC |
WEIGHT | 1.7 Kg - 7 Kg (inc. 2 x 7 AH 12 V bat.) |
DIMENSIONS | 273 (L) x 107 (W) x 404 (H) mm |
COLOUR | Red & White |
Description
ORION
Conventional Fire Detection Panel
The ORION conventional control panel range offers a creatively designed and visually pleasing solution for
smaller cost-conscious projects demanding simplicity of operation. Versions available include 2, 4 and 8 zone
panels and two styles of repeater.
The outstanding programmable features included in this panel range contradict the facilities commonly available
in this type of panel and include: programmable time delay by zone, Day/Night mode, selectable non-latching
zones and coincidence detection.
Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the one
man test mode which provides simple and efficient testing of the system.
Advanced configuration solutions include the following: a dedicated RS232 communication interface allowing
connection of up to 4 remote repeater panels, addressable loop interface modules and multiplexed zonal output
relays; giving one of the most highly advanced levels of system integration and compatibility existing on the
market at this level.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Global Fire Conventional Panel ORION 2-4-8” Cancel reply
Related Products
-
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
-
0 out of 5
Standard 2-8 Zone Conventional Fire Alarm Panel-C-tech
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13. compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits*
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
-
0 out of 5
TD-3332H4
Features
Support 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 / H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
Reviews
There are no reviews yet.