Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm²
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm²
Power supply specification
Main supply voltage: 13V to 27Vdc
Nominal main supply voltage 20Vdc
Quiescent current 20-30µA
Alarm current: 32ma
Mechanical characteristics
Unit weight: 130g
Unit dimensions (in mm): H:55, D:104
Unit row material: ABS
Unit colour: White
Protection class: IP32
Climatic characteristics
Operating temperature: -10°C to +50°C
Storage temperature: +10°C to +50°C
Operating relative humidity: ≤ 93%
Storage relative humidity: ≤ 85%
Description
Both Temperature heat detectors analyze the ambient temperature by the means of thermistor type CTN.
TSC05 (static heat detector) is either classified A1S or BS according to EN54-5 standard:
TSC05-A1S: static T°=62°C±3°C
TSC05-BS: static T°=75°C±5°C
TRC05 (static + rate of rise detector) is especially adapted for average ambient temperature conditions
under +10°C. TRC05 is classified A1R according to EN54-5 standard:
Static T°=62°C±3°C
ΔT°>9°C/min
Both types include a developed technology (microprocessors, smd components) which means precision
and high reliability. A specific head detection fixed by a single ceiling base.
12V version of TRC05 & TSC05 detectors is also available for security type systems
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Conventional heat detectors TS/TR” Cancel reply
Related Products
-
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management -
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Conventional Smoke Detector GFE-C
Key Features
- Dual LEDs for 360º visibility
- Advanced detection and communication protocols
- Easy installation and maintenance
- Sleek low-profile housing
- Durable sensor head, no need for replacement
- SMD circuit board design. High quality and reliability guaranteed
- Sensor Base Option: Regular GFE Detector Base or Deep Base
-
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
-
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
Reviews
There are no reviews yet.