Deactivation Pad
- Dimensions: 40 cm (15.7″) x 28 cm (11″) x 2.5 cm (.98″)
- Frequency: 8.2 MHz
- Power Input: 12VAC 200mA
- Deactivation Distance: 4×4 cm Label 20 cm 5×5 cm Label 20 cm
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
- Dimensions: 40 cm (15.7″) x 28 cm (11″) x 2.5 cm (.98″)
- Frequency: 8.2 MHz
- Power Input: 12VAC 200mA
- Deactivation Distance: 4×4 cm Label 20 cm 5×5 cm Label 20 cm
The Universal Deactivator is an instrument used to deactivate the adhesive RF labels at the point of sale.
A low power transceiver detects a label when it enters the detection area. A signal is then sent to the deactivation unit, which will then send out a deactivation signal. Ultimately, the deactivation signal deactivates the label in 2 microseconds. An audible beep indicates that the label has been permanently deactivated.
- Dimensions: 40 cm (15.7″) x 28 cm (11″) x 2.5 cm (.98″)
- Frequency: 8.2 MHz
- Power Input: 12VAC 200mA
- Deactivation Distance: 4×4 cm Label 20 cm 5×5 cm Label 20 cm
Specifications:
- RF Deactivator
- 7.6MHz- 8.8MHz
- 120pcs/min
- 25cm
- 20cm
Description
The Universal Deactivator is an instrument used to deactivate the adhesive RF labels at the point of sale.
A low power transceiver detects a label when it enters the detection area. A signal is then sent to the deactivation unit, which will then send out a deactivation signal. Ultimately, the deactivation signal deactivates the label in 2 microseconds. An audible beep indicates that the label has been permanently deactivated.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Deactivation Pad” Cancel reply
Related Products
-
0 out of 5
Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction -
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm²
Reviews
There are no reviews yet.