HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
Electrical specification
Mains supply voltage: 230Vac (-15%,+10%), 50Hz or 60Hz
Operating voltage: 26.4V to 29 Vdc
Wiring: 2 x (0,6 to 1,5) mm² max, shielded / Length = 1500m max
Batteries: 2 x 12V/7Ah
Autonomy without mains: 1 hours in alarm (command)
Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 5 A
Mechanical characteristics
Dimensions (mm) / weight (without batteries) 320 x 610 x 175 (h x w d) / 5Kg (without batteries)
Material/colour ABS 5V/RAL 7035
Climatic characteristics
Operating temperature / Storage temperature -10°C to 50°C
Operating relative humidity / Storage relative humidity 93% R.H./ 80% R.H.
Inputs/outputs
Base: Max number of points / Max number of zones 400 points/1000 zones
Base: Fire detection lines 2 loops or 4 open lines
Fire alarm management Alarm, pre alarm, alarm confirmation, hours management
day/night mode
Memory events Up to 2700 events with date and hours
Programmable outputs (fire alarm, fault, test zone, disabled
point...) 3 x free contact relay outputs 50V/0,3A
Programmable inputs (power. supply fault, reset, sounders
activation...)
2 x monitored inputs for external event management (fault,
reset...)
2 x monitored inputs on front panel
Serial communication ports
RS232 communication port programming with PC
RS422 communication port for Jbus protocol for graphic
monitoring
On front panel
RS232 for external printer
2 x RS485 communication port for remote front panel
(redundant communication)
Sounders line 2 x monitored outputs 30V/1A (for the 2 lines)
External power supply output 1 x 24V/0,5A
Internal options
C20R, 20 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R7P2, 7 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R12P2, 12 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
External options
ALPHA RE remote control and indicating panel Serial connection (from 1 to 20 panels)
Description
HEPHAIS 1600 NE is a control and indicating equipment (CIE) with zone and point address localization
using microprocessor-based technology. It is designed to meet the requirements of standards EN54-2
and EN54-4.
HEPHAIS 1600 NE is an interactive-addressable panel and it can manage up to 400 devices on 2
loops of detection or 128 addresses on 4 lines.
The panel is made of a basis CPU board and control front panel. Optional remote front panel, relay
module boards and sounder line splitter are also available.
With its new functionalities, HEPHAIS 1600 NE provides a flexible solution for all Fire Detection
Systems (FDS.
HEPHAIS 1600 NE is reliable and easy to use equipment. Associated to interactive 05 detectors range,
It is adapted to all types of required topologies and can manage up to 400 detectors or manual call
points, that can be equipped of short-circuit isolator.
Adapted to a large scale of application, HEPHAIS 1600 NE can answer to requirements of buildings like
hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office
buildings, back office centres, thanks to its various and numerous outputs allowing many signalling and
command orders.
Field configuration, scheduled sensitivity and the manual setting constitute very useful start up modes
which make HEPHAIS 1600 NE installation a quick and sure operation.
The software TELEHEPHAIS1600 (download data) allows to configure advanced functionalities and
exploit all the capacities of the panel up to 1000 zones and 256 command groups
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 1600 Addressable Panel” Cancel reply
Related Products
-
0 out of 5
Conventional Smoke Detector GFE-C
Key Features
- Dual LEDs for 360º visibility
- Advanced detection and communication protocols
- Easy installation and maintenance
- Sleek low-profile housing
- Durable sensor head, no need for replacement
- SMD circuit board design. High quality and reliability guaranteed
- Sensor Base Option: Regular GFE Detector Base or Deep Base
-
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
Reviews