HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups)
Electrical specification
Mains supply voltage: 230Vac (-15%,+10%), 50Hz or 60Hz
Operating voltage: 26.4V to 29 Vdc
Wiring: 2 x (0,6 to 1,5) mm² max, shielded / Length = 1500m max
Batteries: 2 x 12V/7Ah
Autonomy without mains: 1 hours in alarm (command)
Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 5 A
Mechanical characteristics
Dimensions (mm) / weight (without batteries) 320 x 610 x 175 (h x w d) / 5Kg (without batteries)
Material/colour ABS 5V/RAL 7035
Climatic characteristics
Operating temperature / Storage temperature -10°C to 50°C
Operating relative humidity / Storage relative humidity 93% R.H./ 80% R.H.
Inputs/outputs
Base: Max number of points / Max number of zones 400 points/1000 zones
Base: Fire detection lines 2 loops or 4 open lines
Fire alarm management Alarm, pre alarm, alarm confirmation, hours management
day/night mode
Memory events Up to 2700 events with date and hours
Programmable outputs (fire alarm, fault, test zone, disabled
point...) 3 x free contact relay outputs 50V/0,3A
Programmable inputs (power. supply fault, reset, sounders
activation...)
2 x monitored inputs for external event management (fault,
reset...)
2 x monitored inputs on front panel
Serial communication ports
RS232 communication port programming with PC
RS422 communication port for Jbus protocol for graphic
monitoring
On front panel
RS232 for external printer
2 x RS485 communication port for remote front panel
(redundant communication)
Sounders line 2 x monitored outputs 30V/1A (for the 2 lines)
External power supply output 1 x 24V/0,5A
Internal options
C20R, 20 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R7P2, 7 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
R12P2, 12 way programmable relays board NO/NC contacts potential free or resistive 50V/0,3A
External options
ALPHA RE remote control and indicating panel Serial connection (from 1 to 20 panels)
Description
HEPHAIS 1600 NE is a control and indicating equipment (CIE) with zone and point address localization
using microprocessor-based technology. It is designed to meet the requirements of standards EN54-2
and EN54-4.
HEPHAIS 1600 NE is an interactive-addressable panel and it can manage up to 400 devices on 2
loops of detection or 128 addresses on 4 lines.
The panel is made of a basis CPU board and control front panel. Optional remote front panel, relay
module boards and sounder line splitter are also available.
With its new functionalities, HEPHAIS 1600 NE provides a flexible solution for all Fire Detection
Systems (FDS.
HEPHAIS 1600 NE is reliable and easy to use equipment. Associated to interactive 05 detectors range,
It is adapted to all types of required topologies and can manage up to 400 detectors or manual call
points, that can be equipped of short-circuit isolator.
Adapted to a large scale of application, HEPHAIS 1600 NE can answer to requirements of buildings like
hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office
buildings, back office centres, thanks to its various and numerous outputs allowing many signalling and
command orders.
Field configuration, scheduled sensitivity and the manual setting constitute very useful start up modes
which make HEPHAIS 1600 NE installation a quick and sure operation.
The software TELEHEPHAIS1600 (download data) allows to configure advanced functionalities and
exploit all the capacities of the panel up to 1000 zones and 256 command groups
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 1600 Addressable Panel” Cancel reply
Related Products
-
0 out of 5
Standard 2-8 Zone Conventional Fire Alarm Panel-C-tech
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13. compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits*
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
-
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control
Reviews
There are no reviews yet.