• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty
Operating Voltage Range: 8 to 30VDC (Nominal 12/24VDC)
Maximum Standby Current: @250C 70µA @ 24VDC
Maximum Permissible Alarm Current: 80mA (current limited by control panel)
Environmental Specifications
Application Temperature Range: (see note 1) -300 C to 700C
Humidity: 5% to 95% Relative Humidity (non-condensing)
Mechanical Information
Height: 40.5mm (plus 9.5mm for standard base)
Diameter: 102mm
Weight: 70g (plus 45g for standard base)
Wire Gauge for Terminals: 0.4mm2 to 2.0mm2
Colour: Approximates to RAL9016
Material: ABS
Description
The ECO1005 A thermal detector belongs to System Sensor’s ECO1000 range of detectors. ECO1000 is a range of conventional detectors, which have been produced using the latest in manufacturing technology and supplied with an array of advanced features, making them ‘better by design’. The ECO1005 A thermal detector uses a state of the art thermal element combined with an application specific integrated circuit (ASIC)to provide quick and accurate
detection of fires. The detector incorporates both rate of rise and static elements and is suitable for all areas where the ambient conditions do not normally exhibit rapid changes in temperature.
A laser-based hand held Remote Test Unit can be used in conjunction with the range of ECO1000 detectors for alarm test purposes. The unit transmits a coded message, preventing spurious alarms being generated by other laser-based devices. With a range of several metres, the hand held test unit provides an effortless way of remotely alarm testing the range of ECO1000 detectors and removes the need for any direct physical access to the detector by the user.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Honeywell Gent Conventional Heat Detector : Eco 1005” Cancel reply
Related Products
-
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
-
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box
Reviews