Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Dimensions: 42mm (optical) or 50mm (thermal) ø 102mm
Operating Voltage: 8 – 30VDC (nominal 12 or 24VDC)
ECO Bases: ECO1000B Standard base
ECO1000BSD Standard base with Schottky diode
Accessories: ECO1000RTU Remote test unit
Part Numbers: Optical + base ECO 1003 + Base
Optical ECO 1003
Optical thermal + base ECO 1002 + Base
Optical thermal ECO 1002
Standard base ECO 1000B
Diode base ECO 1000BSD
Thermal + base ECO 1005 + Base
Thermal ECO 1005
ECO1002 COMBINED PHOTO THERMAL
Typical Standby Current: 240μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000; EN54-5:2000 Class A1R; CEA4021
ECO1003 PHOTO-ELECTRIC DETECTOR
Typical Standby Current: 110μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000
ECO1005 RATE OF RISE THERMAL DETECTOR
Typical Standby Current: 125μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 70g
Approvals: Meets EN54-5:2000 Class A1R
Description
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Honeywell Gent Conventional Smoke Detector : Eco 1003” Cancel reply
Related Products
-
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management -
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
-
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box -
0 out of 5
Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm² -
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
Reviews
There are no reviews yet.