F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Dimensions: 42mm (optical) or 50mm (thermal) ø 102mm
Operating Voltage: 8 – 30VDC (nominal 12 or 24VDC)
ECO Bases: ECO1000B Standard base
ECO1000BSD Standard base with Schottky diode
Accessories: ECO1000RTU Remote test unit
Part Numbers: Optical + base ECO 1003 + Base
Optical ECO 1003
Optical thermal + base ECO 1002 + Base
Optical thermal ECO 1002
Standard base ECO 1000B
Diode base ECO 1000BSD
Thermal + base ECO 1005 + Base
Thermal ECO 1005
ECO1002 COMBINED PHOTO THERMAL
Typical Standby Current: 240μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000; EN54-5:2000 Class A1R; CEA4021
ECO1003 PHOTO-ELECTRIC DETECTOR
Typical Standby Current: 110μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000
ECO1005 RATE OF RISE THERMAL DETECTOR
Typical Standby Current: 125μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 70g
Approvals: Meets EN54-5:2000 Class A1R
Description
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Honeywell Gent Conventional Smoke Detector : Eco 1003” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display -
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.