ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box
Electrical specification
Mains supply voltage: 230V +10%/-15% ~ 50Hz/60Hz
Maximum absorbed current from mains: < 110mA
Min/max output voltage: Min=21V, max=28,5V
Batteries: 2 sealed lead batteries connected in series, 12V 4Ah
Mechanical characteristics
Unit dimensions (in mm): 300 x 260 x 125 (h x w x d)
Material: White plastic box (IP 30)
Climatic characteristics
Operating temperature: -5°C ± 3°C... 40°C ± 2°C
Operating relative humidity: 93% with no condensation
Outputs
1 monitored sounders line: 27V/0,5A
1 auto powered sounders line: 27V/1A
1 external power supply output: 27V/0,5A*
1 resettable power supply output: 27V/0,5A*
1 Alarm NC/NO & 1 Fault NC/NO relay contact: 30V/1A
1 programmable open collector output (repetition of
fault, pre-alarm, alarm, silence buzzer, disable): 30V/30mA
Description
The ALPHA 2 unit is a fire detection panel. It has been developed and engineered according to European
standards: EN 54-2 and EN 54-4.
It has 2 resistive monitored conventional lines which are physically separated. The panel can receive at
maximum 64 detectors and/or manual call points in total.
Each zone has visualization indicators which give immediate signalization of alarm, fault and
enabling/disabling. All signalisations of the panel are available through leds and piezoelectric buzzer.
Control functions are available on a membrane keyboard.
ALPHA 2 is recommended for small conventional installations with 64 points maximum.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “ALPHA 2 – 2 zones fire detection conventional panel” Cancel reply
Related Products
-
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm² -
0 out of 5
TD-2700TE-PR
Features
8 / 16 CH TVI / CVI / AHD video input
8 / 16 CH 5MP / 4MP / 4MP lite / 3MP / 1080P / 720P / WD1 recording
4 / 4 CH IPC 4MP / 3MP / 1080P / 960P / 720P recording
Adopt standard H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphics User Interface ( GUI ), window style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 CH simultaneously playback
Search: time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex: preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol, IE browse and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log review and device status review
HDMI 4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
-
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort