ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
Electrical specification
Mains supply voltage: 230V ~ 50 / 60 Hz
Operating voltage: 27Vdc
Wiring: From 0,5 mm2 (500m max) to 2,5 mm ²
Batteries: 2 x 12V/7,2AH
Maximum current supplied: 1A
Mechanical characteristics
Dimensions (mm) / weight (without batteries): 300x370x118 (h x w x d) / 2Kg
IP rating: IP 31
Climatic characteristics
Operating temperature: 0°C to 50°C
Inputs/outputs
AR4D base detection module: 4 detection lines (128 points)
1 monitored programmable input: external power supply state monitoring (standard configuration), external sounders
line activation, external reset panel
1 monitored sounders line: 24V/450mA
1 monitored external power supply output: 24V/450mA
4 programmable open collector outputs: alarm, pre-alarm, disabled, test, system fault, power supply
fault, fault warning, evacuate, active, buzzer on,
reset: 40V/0,1A
1 Alarm NC/NO & 1 Fault NC/NO relay contact: 30V/1A
Options
REP4R, R4P2, R7P2, & R12P2 4, 7, & 12 potential free contact relays boards 30V/1A
EX4A4 detection module 4 detection lines (32 det./line)
DEAG extinguishing module
- Extinguishing actuators line (solenoid or pyroelectric), 24Vdc/1,2A
- Indicators/sounders line, 24Vdc/1A
- Manual extinguishing line
- Inhibition line
- Pressure contact line
- External power supply
Description
ALPHA 4/8/12, modular, compact and economic, is the adapted solution for small installations.
It is microprocessor controlled with SMD technology and with panel programming it is easy to use and install.
With its 4 zones in the basic version and its design, it is adapted for small installations.
Thanks to its optional modules, ALPHA 4/8/12 can be extended to 12 detection zones maximum (384 conventional points) or 2 extinguishing channels maximum (1 extinguishing channel per extinguishing module). Thanks to its 2 slots ALPHA 4/8/12 can provide the following optimal solutions:
4 detection zones + 2 extinguishing channels
8 detection zones + 1 extinguishing channel
12 detection zones
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “ALPHA 4/8/12 Conventional fire detection panel” Cancel reply
Related Products
-
0 out of 5
Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
-
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box -
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display -
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
Reviews
There are no reviews yet.