Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Dimensions: 42mm (optical) or 50mm (thermal) ø 102mm
Operating Voltage: 8 – 30VDC (nominal 12 or 24VDC)
ECO Bases: ECO1000B Standard base
ECO1000BSD Standard base with Schottky diode
Accessories: ECO1000RTU Remote test unit
Part Numbers: Optical + base ECO 1003 + Base
Optical ECO 1003
Optical thermal + base ECO 1002 + Base
Optical thermal ECO 1002
Standard base ECO 1000B
Diode base ECO 1000BSD
Thermal + base ECO 1005 + Base
Thermal ECO 1005
ECO1002 COMBINED PHOTO THERMAL
Typical Standby Current: 240μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000; EN54-5:2000 Class A1R; CEA4021
ECO1003 PHOTO-ELECTRIC DETECTOR
Typical Standby Current: 110μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000
ECO1005 RATE OF RISE THERMAL DETECTOR
Typical Standby Current: 125μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 70g
Approvals: Meets EN54-5:2000 Class A1R
Description
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Honeywell Gent Conventional Smoke Detector : Eco 1003” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 1600 Addressable Panel
Main characteristics
400 addressable devices
1000 zones, 256 groups of command
Base: 2 loops (200 addr./ loop) or 4 open circuits (32
det./line)
2 programmable inputs / 2 programmable outputs on the
CPU board
2 programmable inputs on the front board
Jbus protocol for remote monitoring software
Detectors management (day/night, scheduled sensitivity,
pre-alarm, alarm confirmation)
Addressable sounders management
Manual/automatic management of monitored sounders line
Download software
Actuators function (activation/deactivation command
groups) -
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box -
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation. -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management
Reviews