ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box
Electrical specification
Mains supply voltage: 230V +10%/-15% ~ 50Hz/60Hz
Maximum absorbed current from mains: < 110mA
Min/max output voltage: Min=21V, max=28,5V
Batteries: 2 sealed lead batteries connected in series, 12V 4Ah
Mechanical characteristics
Unit dimensions (in mm): 300 x 260 x 125 (h x w x d)
Material: White plastic box (IP 30)
Climatic characteristics
Operating temperature: -5°C ± 3°C... 40°C ± 2°C
Operating relative humidity: 93% with no condensation
Outputs
1 monitored sounders line: 27V/0,5A
1 auto powered sounders line: 27V/1A
1 external power supply output: 27V/0,5A*
1 resettable power supply output: 27V/0,5A*
1 Alarm NC/NO & 1 Fault NC/NO relay contact: 30V/1A
1 programmable open collector output (repetition of
fault, pre-alarm, alarm, silence buzzer, disable): 30V/30mA
Description
The ALPHA 2 unit is a fire detection panel. It has been developed and engineered according to European
standards: EN 54-2 and EN 54-4.
It has 2 resistive monitored conventional lines which are physically separated. The panel can receive at
maximum 64 detectors and/or manual call points in total.
Each zone has visualization indicators which give immediate signalization of alarm, fault and
enabling/disabling. All signalisations of the panel are available through leds and piezoelectric buzzer.
Control functions are available on a membrane keyboard.
ALPHA 2 is recommended for small conventional installations with 64 points maximum.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “ALPHA 2 – 2 zones fire detection conventional panel” Cancel reply
Related Products
-
0 out of 5
HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display -
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
ALPHA 4/8/12 Conventional fire detection panel
Main features
From 4 (128 points) to 12 (384 points) conventional
detection lines
2 Extinguishing zones manageable
32 detectors and/or MCP each line
Monitored sounders line
Day/night mode
Keyboard programmable ad access level 3
Easy management -
0 out of 5
Conventional Sounder VALKYRIE CS
VALKYRIE CS
Conventional Wall Mount Sounder/ Beacon
The VALKYRIE CS is a wall mounted Conventional Sounder/ Beacon with low power consumption. Four different
tones are available and selected using DIL switches 1 and 2.
Both continuous and pulsing outputs are provided via separate negative supply connections allowing for the
presence of differentiated evacuation and alert sounds. -
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation.