Honeywell Gent Conventional Smoke Detector : Eco 1003
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
F E A T U R E S
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Dimensions: 42mm (optical) or 50mm (thermal) ø 102mm
Operating Voltage: 8 – 30VDC (nominal 12 or 24VDC)
ECO Bases: ECO1000B Standard base
ECO1000BSD Standard base with Schottky diode
Accessories: ECO1000RTU Remote test unit
Part Numbers: Optical + base ECO 1003 + Base
Optical ECO 1003
Optical thermal + base ECO 1002 + Base
Optical thermal ECO 1002
Standard base ECO 1000B
Diode base ECO 1000BSD
Thermal + base ECO 1005 + Base
Thermal ECO 1005
ECO1002 COMBINED PHOTO THERMAL
Typical Standby Current: 240μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000; EN54-5:2000 Class A1R; CEA4021
ECO1003 PHOTO-ELECTRIC DETECTOR
Typical Standby Current: 110μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 75g
Approvals: Meets EN54-7:2000
ECO1005 RATE OF RISE THERMAL DETECTOR
Typical Standby Current: 125μA
Maximum Alarm Current: 50mA (limited by control panel)
Maximum Humidity: 95% RH
Operating Temperature: -20 to +60ºC
Weight: 70g
Approvals: Meets EN54-5:2000 Class A1R
Description
- Photo-thermal model
- Laser-based remote test unit
- EN 54 Certified (2000 edition)
- Photoelectric, photo-thermal and thermal detectors
- Improved chamber design
- Compatible with fire and security systems
- -20 to +60ºC operating temperature range
- Choice of bases (including a 12V relay version)
- Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement)
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Honeywell Gent Conventional Smoke Detector : Eco 1003” Cancel reply
Related Products
-
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
-
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation. -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
Honeywell Gent Conventional Heat Detector : Eco 1005
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty -
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
Reviews
There are no reviews yet.